Robust Electrical Transformer for High Performance in Extreme Conditions

Product Details
Customization: Available
Application: Power
Phase: Three
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2025

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

to see all verified strength labels (27)
  • Robust Electrical Transformer for High Performance in Extreme Conditions
  • Robust Electrical Transformer for High Performance in Extreme Conditions
  • Robust Electrical Transformer for High Performance in Extreme Conditions
  • Robust Electrical Transformer for High Performance in Extreme Conditions
  • Robust Electrical Transformer for High Performance in Extreme Conditions
  • Robust Electrical Transformer for High Performance in Extreme Conditions
Find Similar Products
  • Overview
  • Product Description
  • Main products
  • Company Profile
  • Company′s advantages
  • Certifications
  • Exhibition
  • Packaging & Shipping
  • FAQ
Overview

Basic Info.

Model NO.
S9/S11-30-2500KVA
Core
Core-type Transformer
Cooling Method
Oil-immersed Type Transformer
Winding Type
Separated Winding Transformer
Certification
ISO9001, CCC, ISO14001
Usage
Single-phase Transformer, Combined Transformer, Power Transformer, Distribution Transformer, Ransmission Transformer
Frequency Characteristics
Power Frequency
Shape of Core
CT
Brand
Hengyi
Maximum Ambient Temperature
+ 60 ºC
Minimum Ambient Temperature
- 45 ºC
Altitude
< 2000m
Maximum Monthly Average Temperature
90% (20 ºC )
Transport Package
Maritime Transport
Specification
0.32m³
Trademark
Hengyi
Origin
China

Product Description


Robust Electrical Transformer for High Performance in Extreme Conditions
Product Description

Robust Electrical Transformer for High Performance in Extreme Conditions


The fully sealed distribution transformer is engineered for use in 10kV / 0.4kV, 50Hz distribution and transformation systems, seamlessly integrating into a variety of settings such as residential and commercial buildings, public facilities, industrial and mining enterprises, power generation facilities, as well as urban and rural power networks. It steadfastly adheres to the stringent GB1094 power transformer standards, ensuring reliability and efficiency.

Robust Electrical Transformer for High Performance in Extreme Conditions
Robust Electrical Transformer for High Performance in Extreme Conditions
Robust Electrical Transformer for High Performance in Extreme Conditions
Use Condition
Able to perform under a maximum ambient temperature reaching up to +40 ºC.
Designed to operate efficiently at a minimum ambient temperature of -25 ºC.
Optimally functions at altitudes less than 1000m.
Sustains peak monthly average humidity levels of up to 90% at 20 ºC.
Strategically installed both indoors and outdoors, provided environments are free from fire, explosion hazards, severe pollution, chemical corrosion, and significant vibration.

Robust Electrical Transformer for High Performance in Extreme Conditions

Technical Data of S11-M 10kV three-phase full seal non excitation voltage regulating distribution transformer
Rated capacity(kVA)  Voltage Combination Connection Symbol No-Load Loss (W) Load Loss (W)75ºC No-Load Current  (%) Short Circuit Impedance (%)
High Voltage (kV) High Voltage Tapping Range(%) Low Voltage (kV)
30 6

10

10.5

11
±5(or) ± 2 × 2.5 0.4 Dyn11( or) Yyn0 100 630/600 2.3 4
50 130 910/870 2
80 180 1310/1250 1.9
100 200 1580/1500 1.8
125 240 1890/1800 1.7
160 280 2310/2200 1.6
200 340 2730/2600 1.5
250 400 3200/3050 1.4
315 480 3830/3650 1.3
400 570 4520/4300 1.2
500 680 5410/5150 1.1
630 810 6200 1 4.5
800 980 7500 1
1000 1150 10300 1
1250 1360 12000 0.9
1600 1640 14500 0.8
2000 1940 18000 0.8
2500 2300 21000 0.6
Technical Data of S11-M 11kV three-phase full seal non excitation voltage regulating distribution transformer
Rated capacity(kVA)  Voltage Combination Connection Symbol No-Load Loss (W) Load Loss (W)75ºC No-Load Current  (%) Short Circuit Impedance (%)
High Voltage (kV) High Voltage Tapping Range(%) Low Voltage (kV)
30 6

10

10.5

11
±5(or) ± 2 × 2.5 0.4 Dyn11( or) Yyn0 80 630/600 2.1 4
50 100 910/870 1.9
80 130 1310/1250 1.8
100 150 1580/1500 1.6
125 170 1890/1800 1.5
160 200 2310/2200 1.4
200 240 2730/2600 1.3
250 290 3200/3050 1.2
315 340 3830/3650 1.1
400 410 4520/4300 1.0 
500 480 5410/5150 1.0 
630 570 6200 0.9 4.5
800 700 7500 0.8
1000 830 10300 0.7
1250 970 12000 0.6
1600 1170 14500 0.6
2000 1360 18000 0.5
2500 1610 21000 0.4
Technical data of S11-M type 20kV three-phase full seal non excitation voltage regulating distribution transformer
Rated capacity(kVA)  Voltage Combination Connection Symbol No-Load Loss (W) Load Loss (W)75ºC No-Load Current  (%) Short Circuit Impedance (%)
High Voltage (kV) High Voltage Tapping Range(%) Low Voltage (kV)
30 20 ±5(or) ± 2 × 2.5 0.4 Dyn11( or) Yyn0 100 690/660 2.1 5.5
50 130 1010/960 2.0
63 150 1200/1150 1.9
80 180 1440/1370 1.8
100 200 1730/1650 1.6
125 240 2080/1980 1.6
160 280 2540/2420 1.4
200 340 3000/2860 1.3
250 400 3520/3360 1.2
315 480 4210/4010 1.1
400 570 4970/4730 1.0
500 680 5940/5660 1.0
630 810 6820 0.9 6
800 980 8250 0.8
1000 1150 11330 0.7
1250 1360 13200 0.7
1600 1640 15950 0.6
2000 1940 19140 0.6
2500 2300 21000 0.5

Technical data of S13-M type 20kV three-phase full seal non excitation voltage regulating distribution transformer
Rated capacity(kVA)  Voltage Combination Connection Symbol No-Load Loss (W) Load Loss (W)75ºC No-Load Current  (%) Short Circuit Impedance (%)
High Voltage (kV) High Voltage Tapping Range(%) Low Voltage (kV)
30 20 ±5(or) ± 2 × 2.5 0.4 Dyn11( or) Yyn0 80 690/660 2.0 5.5
50 100 1010/960 1.9
63 110 1200/1150 1.8
80 130 1440/1370 1.7
100 150 1730/1650 1.5
125 180 2080/1980 1.5
160 200 2540/2420 1.3
200 240 3000/2860 1.2
250 280 3520/3360 1.1
315 340 4210/4010 1.0
400 400 4970/4730 0.9
500 480 5940/5660 0.9
630 570 6820 0.8 6
800 680 8250 0.7
1000 810 11330 0.6
1250 980 13200 0.6
1600 1150 15950 0.5
2000 1360 19140 0.5
2500 1640 22220 0.4
Main Technical Parameters of 800kVA ~ 31500kVA three-phase double winding non Excitation Voltage Regulating Power Transformer
Rated capacity(kVA)  Voltage Combination Connection Symbol No-Load Loss (W) Load Loss (W)75ºC No-Load Current  (%) Short Circuit Impedance (%)
High Voltage (kV) High Voltage Tapping Range(%) Low Voltage (kV)
630 33 ± 5% 3.15
6.3
10.5
Yd11 830 7870 1.1 6.5
800 980 9410 1
1000 1150 11540 1
1250 1410 13940 0.9
1600 1700 16670 0.8
2000 2180 18380 0.7
2500 2560 19670 0.6
3150 33~38.5 3040 23090 0.56 7
4000 3620 27360 0.56
5000 4320 31380 0.48
6300 5250 35060 0.48 7.5
8000 ± 5%
or
± 2 × 2. 5%
3.15
3.3
6.3
6.6
10.5
11
YNd11 7200 38500 0.42
10000 8700 45300 0.42
12500 10080 53900 0.4 8
16000 12160 65800 0.4

20000


14400

79500

0.4
25000 17020 94100 0.32
31500 20220 112900 0.32
Main Technical Parameters of 2000 kVA ~ 20000 kVA Three-Phase Double Winding On-Load Voltage Regulating Power Transformer
Rated capacity(kVA)  Voltage Combination Connection Symbol No-Load Loss (W) Load Loss (W)75ºC No-Load Current  (%) Short Circuit Impedance (%)
High Voltage (kV) High Voltage Tapping Range(%) Low Voltage (kV)
2000 33 ± 3 × 2. 5% 6.3
10.5
Yd11 2300 19240 0.8 6.5
2500 2720 20640 0.8
3150 33~38.5 3230 24710 0.72 7
4000 3870 29160 0.72
5000 4640 34200 0.68
6300 5630 36800 0.68 7.5
8000 6.3
6.6
10.5
11
YNd11 7870 40600 0.6
10000 9280 48100 0.6
12500 10940 56900 0.56 8.0 
16000 13170 70300 0.54
20000 15570 82800 0.54
Main products
Robust Electrical Transformer for High Performance in Extreme Conditions
Company Profile
Robust Electrical Transformer for High Performance in Extreme ConditionsHY TRANSFORMER represents a beacon of innovation and excellence in the realm of high-tech enterprise, predominantly focusing on the sophisticated development, meticulous production, and expansive sales of premier power transformers and auxiliary products. We proudly manufacture a versatile array of distribution transformers, catering to high-performance needs of 35kV and below. Our offerings include the distinguished SC(B)10, SC(B)11, and SC(B)12 series of epoxy resin cast dry-type transformers, alongside the robust non-sealed H grade dry-type power transformer. In addition, we present the superior S series oil-immersed transformers, and the advanced S(B)H15-M and S(B)H16-M sealed amorphous alloy transformers. Expanding our innovative product range, we also deliver the YB series of elegant box substations (European box-type) and the sophisticated combined transformers (American type prefabricated substations), ensuring we meet diverse electrical distribution needs with precision and reliability.
Leveraging years of profound expertise, HY TRANSFORMER remains steadfast in its commitment to the 'top quality' path, consistently maintaining a vanguard position in the transformer industry. Our technologically advanced and high-quality products are extensively utilized across a myriad of sectors, including power grid systems, power supply networks, coal mining, metallurgy, petroleum, chemical industries, construction, ports, airports, railway transportation, urban infrastructure, and beyond. Each of our products proudly boasts certifications such as ISO9001, ISO14001, OHSAS18001, PCCC Energy-saving Product Certification, and a plethora of patent certificates. We rigorously adhere to and continually update national industry standards, ensuring we establish an impeccable management system. By sourcing premium materials and upholding stringent process controls and inspections, we guarantee that every step is meticulously managed, ensuring our systems operate with unmatched efficacy. The unparalleled quality and technical service of our products enjoy recognition and admiration from satisfied customers worldwide. Our business principle, 'Stay with best quality, develop with high reputation,' embodies our pursuit of excellence, and through our 'double-win' methodology, we forge successful partnerships with all stakeholders. Join us in our mission to advance global green electrical power, as we eagerly invite you to experience our products and collaborate in crafting a brighter, more sustainable future. Together, let's envision and construct a beautiful tomorrow!


Robust Electrical Transformer for High Performance in Extreme Conditions
Company's advantages
Robust Electrical Transformer for High Performance in Extreme Conditions
Certifications
Robust Electrical Transformer for High Performance in Extreme Conditions
Exhibition
Robust Electrical Transformer for High Performance in Extreme Conditions
Packaging & Shipping
Robust Electrical Transformer for High Performance in Extreme Conditions
FAQ

Q.Are you a trading company or a manufacturer?
A.We are a professional manufacturer of high and low voltage switchgear, substations, transformers, cable distribution boxes and various electrical equipment. We have accumulated 20 years of experience. Our factory is an outstanding supplier of China State Grid Corporation.

Q. Do you offer customized services?
A.We offer OEM/ODM services and can print your logo on the products. Our professional technical and quotation teams can provide satisfactory projects based on your drawings and parameters.

Q. What is your minimum order quantity?
A.Our minimum order quantity is one piece.

Q. How long is your delivery cycle?
A.This depends on your product requirements and quantity. Generally, it will take 5 to 10 working days.

Q. How do you deal with quality issues?
A.Please provide detailed photos of the quality issues. Our technical and quality inspection departments will conduct an analysis. We will offer a satisfactory solution within two days.

Q. What are your payment terms?
A.30% by wire transfer, 70% before shipment. Western Union remittance, letter of credit are also acceptable.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier