Product Description

Introducing a fully sealed distribution transformer, perfectly compatible with 10kV / 0.4kV, 50Hz distribution and transformation systems, this transformer is a powerhouse of reliability and adaptability, serving an impressive array of environments. Its exceptional versatility makes it ideal for residential, commercial buildings, public facilities, industrial and mining enterprises, power generation companies, as well as both urban and rural power grids. Adhering to the stringent GB1094 power transformer standard, this product ensures superior performance and safety.
Use Condition
The transformer thrives in conditions where the maximum ambient temperature does not exceed +40 ºC.
With a robust design, it can operate seamlessly even when the ambient temperature drops to a chilly -25 ºC.
Built for resilience, it performs optimally at altitudes below 1000m.
During warmer months, it can handle a maximum monthly average temperature of 90% at 20 ºC with ease.
Perfect for both indoor and outdoor installations, this transformer is suitably placed in environments free from fire hazards, explosive risks, severe pollution, chemical corrosion, and intense vibrations.

Technical Data of S11-M 10kV three-phase full seal non excitation voltage regulating distribution transformer
Rated capacity(kVA) |
Voltage Combination |
Connection Symbol |
No-Load Loss (W) |
Load Loss (W)75ºC |
No-Load Current (%) |
Short Circuit Impedance (%) |
High Voltage (kV) |
High Voltage Tapping Range(%) |
Low Voltage (kV) |
30 |
6
10
10.5
11 |
±5(or) ± 2 × 2.5 |
0.4 |
Dyn11( or) Yyn0 |
100 |
630/600 |
2.3 |
4 |
50 |
130 |
910/870 |
2 |
80 |
180 |
1310/1250 |
1.9 |
100 |
200 |
1580/1500 |
1.8 |
125 |
240 |
1890/1800 |
1.7 |
160 |
280 |
2310/2200 |
1.6 |
200 |
340 |
2730/2600 |
1.5 |
250 |
400 |
3200/3050 |
1.4 |
315 |
480 |
3830/3650 |
1.3 |
400 |
570 |
4520/4300 |
1.2 |
500 |
680 |
5410/5150 |
1.1 |
630 |
810 |
6200 |
1 |
4.5 |
800 |
980 |
7500 |
1 |
1000 |
1150 |
10300 |
1 |
1250 |
1360 |
12000 |
0.9 |
1600 |
1640 |
14500 |
0.8 |
2000 |
1940 |
18000 |
0.8 |
2500 |
2300 |
21000 |
0.6 |
Technical Data of S11-M 11kV three-phase full seal non excitation voltage regulating distribution transformer
Rated capacity(kVA) |
Voltage Combination |
Connection Symbol |
No-Load Loss (W) |
Load Loss (W)75ºC |
No-Load Current (%) |
Short Circuit Impedance (%) |
High Voltage (kV) |
High Voltage Tapping Range(%) |
Low Voltage (kV) |
30 |
6
10
10.5
11 |
±5(or) ± 2 × 2.5 |
0.4 |
Dyn11( or) Yyn0 |
80 |
630/600 |
2.1 |
4 |
50 |
100 |
910/870 |
1.9 |
80 |
130 |
1310/1250 |
1.8 |
100 |
150 |
1580/1500 |
1.6 |
125 |
170 |
1890/1800 |
1.5 |
160 |
200 |
2310/2200 |
1.4 |
200 |
240 |
2730/2600 |
1.3 |
250 |
290 |
3200/3050 |
1.2 |
315 |
340 |
3830/3650 |
1.1 |
400 |
410 |
4520/4300 |
1.0 |
500 |
480 |
5410/5150 |
1.0 |
630 |
570 |
6200 |
0.9 |
4.5 |
800 |
700 |
7500 |
0.8 |
1000 |
830 |
10300 |
0.7 |
1250 |
970 |
12000 |
0.6 |
1600 |
1170 |
14500 |
0.6 |
2000 |
1360 |
18000 |
0.5 |
2500 |
1610 |
21000 |
0.4 |
Technical data of S11-M type 20kV three-phase full seal non excitation voltage regulating distribution transformer
Rated capacity(kVA) |
Voltage Combination |
Connection Symbol |
No-Load Loss (W) |
Load Loss (W)75ºC |
No-Load Current (%) |
Short Circuit Impedance (%) |
High Voltage (kV) |
High Voltage Tapping Range(%) |
Low Voltage (kV) |
30 |
20 |
±5(or) ± 2 × 2.5 |
0.4 |
Dyn11( or) Yyn0 |
100 |
690/660 |
2.1 |
5.5 |
50 |
130 |
1010/960 |
2.0 |
63 |
150 |
1200/1150 |
1.9 |
80 |
180 |
1440/1370 |
1.8 |
100 |
200 |
1730/1650 |
1.6 |
125 |
240 |
2080/1980 |
1.6 |
160 |
280 |
2540/2420 |
1.4 |
200 |
340 |
3000/2860 |
1.3 |
250 |
400 |
3520/3360 |
1.2 |
315 |
480 |
4210/4010 |
1.1 |
400 |
570 |
4970/4730 |
1.0 |
500 |
680 |
5940/5660 |
1.0 |
630 |
810 |
6820 |
0.9 |
6 |
800 |
980 |
8250 |
0.8 |
1000 |
1150 |
11330 |
0.7 |
1250 |
1360 |
13200 |
0.7 |
1600 |
1640 |
15950 |
0.6 |
2000 |
1940 |
19140 |
0.6 |
2500 |
2300 |
21000 |
0.5 |
Technical data of S13-M type 20kV three-phase full seal non excitation voltage regulating distribution transformer
Rated capacity(kVA) |
Voltage Combination |
Connection Symbol |
No-Load Loss (W) |
Load Loss (W)75ºC |
No-Load Current (%) |
Short Circuit Impedance (%) |
High Voltage (kV) |
High Voltage Tapping Range(%) |
Low Voltage (kV) |
30 |
20 |
±5(or) ± 2 × 2.5 |
0.4 |
Dyn11( or) Yyn0 |
80 |
690/660 |
2.0 |
5.5 |
50 |
100 |
1010/960 |
1.9 |
63 |
110 |
1200/1150 |
1.8 |
80 |
130 |
1440/1370 |
1.7 |
100 |
150 |
1730/1650 |
1.5 |
125 |
180 |
2080/1980 |
1.5 |
160 |
200 |
2540/2420 |
1.3 |
200 |
240 |
3000/2860 |
1.2 |
250 |
280 |
3520/3360 |
1.1 |
315 |
340 |
4210/4010 |
1.0 |
400 |
400 |
4970/4730 |
0.9 |
500 |
480 |
5940/5660 |
0.9 |
630 |
570 |
6820 |
0.8 |
6 |
800 |
680 |
8250 |
0.7 |
1000 |
810 |
11330 |
0.6 |
1250 |
980 |
13200 |
0.6 |
1600 |
1150 |
15950 |
0.5 |
2000 |
1360 |
19140 |
0.5 |
2500 |
1640 |
22220 |
0.4 |
Main technical parameters of 800kVA ~ 31500kVA three-phase double winding non Excitation is a crucial process that plays a significant role in the efficient functioning of our transformers. By ensuring optimal excitation, we enhance the performance and reliability of our Durable Three Phase Current Transformer for High Voltage Applications. Voltage management is at the heart of our technology. With a focus on maintaining stable and efficient voltage levels, our products support high-performance outcomes and deliver superior reliability for high voltage applications. Regulating capabilities are a hallmark of our product line, ensuring precise control and adaptability in various high voltage applications. Our transformers offer robust performance and consistent results, meeting the demanding needs of modern electrical systems. The power transformer is the powerhouse of our product offerings. It is engineered to deliver exceptional durability and efficiency, making it an ideal choice for high voltage applications demanding top-tier performance.
Rated capacity(kVA) |
Voltage Combination |
Connection Symbol |
No-Load Loss (W) |
Load Loss (W)75ºC |
No-Load Current (%) |
Short Circuit Impedance (%) |
High Voltage (kV) |
High Voltage Tapping Range(%) |
Low Voltage (kV) |
630 |
33 |
± 5% |
3.15
6.3
10.5 |
Yd11 |
830 |
7870 |
1.1 |
6.5 |
800 |
980 |
9410 |
1 |
1000 |
1150 |
11540 |
1 |
1250 |
1410 |
13940 |
0.9 |
1600 |
1700 |
16670 |
0.8 |
2000 |
2180 |
18380 |
0.7 |
2500 |
2560 |
19670 |
0.6 |
3150 |
33~38.5 |
3040 |
23090 |
0.56 |
7 |
4000 |
3620 |
27360 |
0.56 |
5000 |
4320 |
31380 |
0.48 |
6300 |
5250 |
35060 |
0.48 |
7.5 |
8000 |
± 5% or ± 2 × 2. 5% |
3.15
3.3
6.3
6.6
10.5
11 |
YNd11 |
7200 |
38500 |
0.42 |
10000 |
8700 |
45300 |
0.42 |
12500 |
10080 |
53900 |
0.4 |
8 |
16000 |
12160 |
65800 |
0.4 |
20000 |
14400 |
79500 |
0.4 |
25000 |
17020 |
94100 |
0.32 |
31500 |
20220 |
112900 |
0.32 |
Main technical parameters of the 2000 kVA ~ 20000 kVA three-phase double winding on-load voltage regulating power transformer include advanced features that provide unparalleled efficiency and adaptability in high voltage environments. These transformers are meticulously designed to meet the rigorous demands of modern electrical grids, ensuring seamless and reliable operation.
Rated capacity(kVA) |
Voltage Combination |
Connection Symbol |
No-Load Loss (W) |
Load Loss (W)75ºC |
No-Load Current (%) |
Short Circuit Impedance (%) |
High Voltage (kV) |
High Voltage Tapping Range(%) |
Low Voltage (kV) |
2000 |
33 |
± 3 × 2. 5% |
6.3
10.5 |
Yd11 |
2300 |
19240 |
0.8 |
6.5 |
2500 |
2720 |
20640 |
0.8 |
3150 |
33~38.5 |
3230 |
24710 |
0.72 |
7 |
4000 |
3870 |
29160 |
0.72 |
5000 |
4640 |
34200 |
0.68 |
6300 |
5630 |
36800 |
0.68 |
7.5 |
8000 |
6.3
6.6
10.5
11 |
YNd11 |
7870 |
40600 |
0.6 |
10000 |
9280 |
48100 |
0.6 |
12500 |
10940 |
56900 |
0.56 |
8.0 |
16000 |
13170 |
70300 |
0.54 |
20000 |
15570 |
82800 |
0.54 |
Main products
Company Profile
HY TRANSFORMER stands as a beacon of innovation and excellence, proudly operating as a high-tech enterprise dedicated to the advancement, production, and distribution of top-of-the-line power transformers and related solutions. We specialize in manufacturing a diverse range of distribution transformers, expertly handling units up to 35kV and introducing the SC(B)10, SC(B)11, and SC(B)12 series of epoxy resin cast dry-type transformers. Our offerings also include Non-sealed H grade dry-type power transformers, the robust S series oil-immersed transformers, and the energy-efficient S(B)H15-M and S(B)H16-M sealed amorphous alloy transformers. Additionally, we provide the YB series of box substations (European box-type) and the Combined transformer (American type prefabricated substation), each engineered for superior performance and reliability.
With a wealth of experience, HY TRANSFORMER steadfastly pursues the 'top quality' pathway. Our technological prowess and uncompromising standards have set us at the forefront of the transformer industry. Our state-of-the-art products find their place in a myriad of sectors including power grid, power supply, coal, metallurgy, petroleum, chemical, construction, port, airport, railway transportation, and urban infrastructure, to name a few. Our unwavering commitment to excellence is validated through our certifications – ISO9001, ISO14001, OHSAS18001, PCCC Energy-saving Product Certification – and numerous patent certificates. We diligently adhere to national industry standards while implementing a meticulous management system that emphasizes premium material procurement, precise processes, and rigorous inspection protocols. This ensures each step is meticulously controlled, guaranteeing an effective system operation. Our superior quality and technical service have garnered global recognition and trust. Guided by the principle of 'Stay with best quality, develop with high reputation', we embrace a 'double-win' partnership ethos, striving for mutual success with our collaborators. Join us in championing the advancement of green electrical power worldwide. Together, let's forge a brighter, sustainable future!
Company's advantages
Certifications
Exhibition
Packaging & Shipping
FAQ
Q.Are you a trading company or a manufacturer?
A.We are a professional manufacturer of high and low voltage switchgear, substations, transformers, cable distribution boxes and various electrical equipment. We have accumulated 20 years of experience. Our factory is an outstanding supplier of China State Grid Corporation.
Q. Do you offer customized services?
A.We offer OEM/ODM services and can print your logo on the products. Our professional technical and quotation teams can provide satisfactory projects based on your drawings and parameters.
Q. What is your minimum order quantity?
A.Our minimum order quantity is one piece.
Q. How long is your delivery cycle?
A.This depends on your product requirements and quantity. Generally, it will take 5 to 10 working days.
Q. How do you deal with quality issues?
A.Please provide detailed photos of the quality issues. Our technical and quality inspection departments will conduct an analysis. We will offer a satisfactory solution within two days.
Q. What are your payment terms?
A.30% by wire transfer, 70% before shipment. Western Union remittance, letter of credit are also acceptable.